  • Design of Residential Building with Vertical Setback

Patel Keyurkumar Bharatbhai

5739

Design of Residential Building with Vertical Setback

The project is a building with a vertical setback located in Zone IV, right portion of the building extends up to G+3 and the left portion up to G+8.Due to this, torsion is generated in the structure which needs to be mitigated. This is done by introducing shear walls at appropriate locations. As a result of this, torsion is induced in opposite directions in the right and left portions of the building which nullifies the effect of torsion in the structure. 


Report Content

Problem Statement & Architectural Drawing

Introduction to Problem Statement

Summary of Loads

Behavior of Initial model

Evolution of Structural System

Final Structural System

Behavior of Final Structural System

Comparison of Torsional Behavior of both initial and final model

Location of Center of Mass and Center of Stiffness at each floor

Calculation of % earthquake load taken by each frame & Summary