Rohit Harwani

CT3005

Structural Failure

The building is located in puri near coastal area. The visual observation is done in the building to know the distresses in the elements and to locate the positions in the drawing. STAAD pro software is used to gain the results of the structural capacity of distressed elements that needs to be repaired. By performing the calculation the capacity of the damaged elements & the repair methodologies were suggested. Different repaired methodologies are suggested in this report, like providing extra steel, jacketing, FRP application & patchwork. https://drive.google.com/file/d/1buNnKrMdjZNgVUGmlww6WXEvB-K6hWpo/view?usp=sharing

View Additional Work

Report Content

Introduction

Structure modelling using STAAD

NDT test

Distress mapping

Condition survey

Structural capacity analysis

Beam strengthening using FRP

Beam strengthening using steel plate

Column Jacketing

Slab strengthening

Project Video