For a richer surfing experience on our website, please update your browser. Update my browser now!
This project aim to understand the behavior of various structural elements and to analyze and design the structure under various loading conditions. dead load is calculated based on its material property by referring to different brochure and IS 875 part-1. Live load is calculated by referring to IS-875 part-2. Wind load is calculated by referring to IS-875 part-3. all structural member like purlins ,girts ,truss element, column and connection are designed by IS-800:2007.