Kathiriya Jenish Ramesh

CT2025

Atitaram

We were given the railway station of vastrapur as a site. There was a cantilever roof that we were to redesign. Steps, sharp edges, and eagle wings inspire this design. This new roof stretches 6m southwards from the column (it's also 10 degrees sloping downwards, thus providing more shade) and 6 m northwards from the column.  

View Additional Work

Report Content

Redesigned case study house

Site analysis of railway station

Plans

Elevation and Section

Structural and member drawings

Joinery and Foundation detail

Staad iterations of the new designed roof

Manual calculations

Rendered 3D model

1:20 Model

Project Video