Steel roof structures provide excellent strength-to-weight performance and allow large, unobstructed spans. Grid-type systems in both single layer and double layer arrangements are commonly used for such applications. Although past research has focused on single layer roofs and square on square double layer arrangements, it often assumes uniform support along all four edges. In practice, roofs may be supported on only two or three edges, which alters load paths and affects the choice of optimal geometry. This study evaluates single layer and double layer grid geometries under different support conditions to determine suitable grid geometry and ideal spacing-to-span ratios.

View Additional Work

Report Content

INTRODUCTION

SINGLE LAYER SCOPE

DOUBLE LAYER SCOPE

COMPARISON ASPECTS & RESEARCH METHODOLOGY

LOADING

SINGLE LAYER GRID COMPARISON

SINGLE LAYER SPACING COMPARISON

DOUBLE LAYER GRID COMPARISON

DOUBLE LAYER SPACING COMPARISON

CONCLUSION