Gorasiya Rahul Jayantilal

SD4004-1

DESIGN OF INDUSTRIAL WAREHOUSE

  This project comprises the complete structural analysis and design of an industrial warehouse, covering all primary and secondary structural members, along with the gantry girder. Plate sections were adopted for the main frames, while cold-formed sections were used for purlins and girts. A comparative study was carried out between gantry girders in laterally unsupported conditions and those laterally supported using a surge girder. For the heavy-duty gantry system, the optimum solution was identified as a laterally supported box-type gantry girder. Seismic loads were applied in accordance with IS 1893:2024, and wind loads were evaluated as per IS 875 (Part 3):2015. The structure had a span of 20 m; however, after the removal of two intermediate columns, the effective spans increased to 40 m in the X-direction and 21.75 m in the Z-direction. 

View Additional Work

Report Content

PROBLEM STATEMENT & PROJECT DETAILS

LOAD CONSIDERATION AND NET WIND ROOF/WALL CO-EFFICIENTS

GANTRY GIRDER ANALYSIS & DESIGN

GANTRY GIRDER ANALYSIS & DESIGN

SUMMARY OF GANTRY GIRDER DESIGN ITERATIONS

BEHAVIOUR OF 2-D FRAME

3-D MODELLING & SECONDARY ELEMENTS

PURLIN & GIRTS DESIGN

CONNECTIONS

% STEEL CONSUMPTION & LEARNING OUTCOMES