Pranami Jugalkumar Dharmendrabhai

SD4004-3

Design of Transfer Tower: A staging structure

This project involves the analysis and design of  Transfer tower: A staging structure located at Port Blair, Andaman Nicobar. The structure has been evaluated for dead, live, wind, seismic, and equipment loads in accordance with IS 800:2007, IS 875 Parts 1, 2, and 3, and IS 1893:2016 Part 1 and IS 1893:2024 Part 4. Wind loads have been applied to the roof, beams, columns, and equipment as the structure is open from all sides. All structural members are designed with plate members of grade Fy 350, having all junctions as shear connection. The project also includes a Comparison study of Standard steel beam and Composite beam. Design of the composite beam is done as per IS 11384:2022.


Report Content

Problem statement

Structural system

wind Load calculation

Earthquake Load calculation & Purlin design

Flooring design & Iteration for built-up section

Design of beam & Column

Bracing design & Deflection check

Design of Monorail & Final Steel take-off

Typical connection detailing

Comparison: Steel Beam V/S Composite beam