In CT2014 Plumbing Design Studio, I traced water from source to sewer. I began with my own flat: borewell, UG tank, pumps and fixtures, measuring 210 L per person a day against NBC's 135 L. Research on water circularity and the 7R framework shaped my resort design in Goa for 1,834 people, sizing demand, treatment, pumps, drainage and recharge to NBCS 2026. Reusing treated sewage saves 36.2 % freshwater daily, and site levels let the sewer run by gravity. Our group built HydroSense, a dry-wall toilet block that locates hidden leaks to within 5 cm. Site visits connected design to real practice.