Vatsal Denishbhai Thacker

CT3021

EARTHEN-O-OFFICE

This project compares traditional Bhunga architecture with modern post-earthquake brick–concrete housing in Bhuj to understand how form and materials affect thermal comfort and energy performance. The Bhunga, with its circular shape, thick mud walls, and thatched roof, naturally remains cool by minimizing heat gain and maximizing thermal lag, resulting in very low cooling loads and stable indoor temperatures. In contrast, modern RCC studios with flat concrete roofs and brick walls absorb and store large amounts of heat, causing overheating and significantly higher cooling energy demand. Simulations clearly show that the Bhunga performs best—with the lowest annual energy use and uniform daylight—while the studio form performs worst, with the highest temperature fluctuations and energy consumption. This brief establishes the need to adopt vernacular principles—compact forms, earth materials, and breathable roofs—to create a climate-responsive, low-energy workspace for Bhuj.

View Additional Work

Report Content

Dwelling Documentation

Daylight Performance Analysis of Dwelling

Energy Performance Analysis of Dwelling

Climate Analysis of Bhuj;s Warm-Humid climate

Case Study on Traditional Architecture of Bhuj- BHUNGA

Case Study on Contemporary Architecture of Bhuj- Mass Post Earthquake Construction

Developing Design: Choosing Site Context, material, size, shape and form

Base Case Analysis of Thermal and Energy performance

Thermal and Energy Analysis of BHUNGA with traditional materials

Analysis of Traditional vs Contemporary architecture- Thermal and Energy Performance based on shape and material