Serkhel Mohsin Ramzan Hameeda

SD4007-2

Stone Tapering Vault Cafeteria

Stone Tapering Vault is a cafeteria roof for the Kund at CEPT University, Ahmedabad, built only of limestone and carried by its own weight. A 25 m catenary vault tapers from a 12 m span to 6 m, keeping the thrust inside the section so the stone stays in compression. STAAD checks against IS 1905 give a peak stress of 0.298 N/mm² against 0.323 allowed, and the taper saves about 25% of the stone. The vault is then opened into a 300 mm lattice with a side arch, where grouted steel bars carry the tension.


Report Content

The layout plan of the Kund workshop area at CEPT University shows a tapering 25 m strip. The covered dining zone follows that taper, with the transverse span growing from 6 m to 12 m and space for about 80 people. Stone is the only structural material, and the roof carries only its own weight. Next to it, a 25 m open refreshment zone holds the service stalls, separate from the covered structure. The design problem is a roof that responds to stone behaviour and to the changing width at the same time: a stone roof is only safe if its force path stays in compression.

Limestone is strong in compression and weak in tension. It is also brittle, heavy and built from blocks, so the form must keep the line of thrust inside the section. For a 300 mm section the middle third is ±50 mm (t/6): while the thrust line stays inside it, the whole section is in compression, and once it leaves, one face goes into tension and joints can open. Every check in this project tests this rule. Stress is checked against the IS 1905 limit of 0.323 N/mm² in compression and 0.07 N/mm² in tension. Limestone suits arches, vaults and shells, and it is a regional stone.

Two built precedents showed that an open stone roof can work in compression. The Stone Matters Pavilion in Jericho is a 7 × 7 m limestone lattice whose interlocking units gather forces at defined supports. The Sidi Saiyyed Mosque in Ahmedabad uses arches and thick piers to carry roof loads and thrust down. Three early ideas for the cafeteria (arches carrying a cafe floor, crossing barrel vaults, and an open curved roof) showed where the supports must go. What was kept: arches, a single tapering vault along the 25 m site, and a continuous curved profile. A stone roof need not be solid, but its compression path must stay intact.

The first model was a stone lattice roof with a side-opening arch and repeated transverse arches that split the 25 m into shorter bays. The mid-semester review found a stiffness mismatch: the stiff arches attract load first, so the lattice between them is left to bend. Bending turns axial compression into flexure and tension, which stone cannot take, and once the thrust line leaves the middle third (±50 mm for 300 mm) a face cracks. The design response was to remove the arches and treat roof and supports as one continuous tapering vault under self-weight, first proving it is compression-only, then reopening it as a lattice.

A hanging chain works in pure tension, and inverted it becomes a catenary that works in pure compression, so the bending moment is zero. A semicircular arch fails this test: its thrust line sits up to 306 mm off-centre, against the 50 mm allowed (t/6 for a 300 mm section). For a 1 m strip with a 7.5 kN/m² self-weight, the catenary gives a springing stress of 0.121 N/mm² at the 6 m span and 0.243 N/mm² at the 12 m span. Even the 12 m span uses only 75% of the IS 1905 allowable compression of 0.323 N/mm².

A 12 m span, 6 m rise catenary vault, 25 m long and 300 mm thick, is modelled with pinned springings under self-weight only. Every cross-section is the same, so the hand calculation applies at any point along the length. The contours show compression everywhere, highest at the springing and lowest at the crown, with peak stress 0.298 N/mm² against the 0.323 N/mm² limit. Tension appears only at the free ends, at about 0.007 N/mm² against 0.07 permitted. STAAD matches the hand calculation: support reactions agree within about 3%. This vault is the baseline for the tapering vault.

The span narrows from 12 m to 6 m along the 25 m length, so each section is a smaller arch with less thrust than the one beyond it. The compression contours tilt into a wedge: springing stress grows from about 0.136 to 0.204 N/mm² between x = 5 m and x = 20 m, where the typical vault holds about 0.22 at every section. Peak compression is 0.275 N/mm² against the 0.323 N/mm² limit (85%), and peak tension is 0.010 N/mm² against 0.07, a local effect at the ends. STAAD matches the hand calculation within about 2%, and the taper uses about 25% less stone.

When the solid vault is opened into a 300 × 300 mm lattice, bending and tension return to the members. In the STAAD model the largest compression is 1.456 N/mm² and the largest tension is 0.824 N/mm², against limits of 0.323 and 0.07, so about 59% of members exceed the tension limit. The worst-bending member, beam 511, has 0.612 N/mm² of tension, about nine times the limit, so the lattice needs steel. Larger cells make it worse. The stiff 1 × 1 m side arch attracts load into the lattice, raising the largest tension to 1.66 N/mm², with 64% of members over the limit.

Stone takes no tension, so the steel must carry it. Each 300 × 300 mm member gets four grouted steel bars, one in each corner, 75 mm from the faces. Two bars would leave a corner bare, and a diagonal crack could run through it. The size comes from a cracked-section check: find the steel stress with a modular ratio of 8 and keep it below 150 N/mm². Beam 511, the worst-bending member, works at 81 N/mm² with 8 mm bars. Member 30 has a tension zone of only 64 mm and needs about 9 mm² of steel. After cracking, the stone's own compression becomes the limit.

The roof began as a 25 m stone cafeteria roof at Kund that narrows from 12 m to 6 m. A catenary keeps its thrust inside the section, so the stone works in compression, and hand calculation and STAAD agree that the tapering vault is safe, with about 25% less stone. Opening it into a lattice brought tension back, so grouted steel bars now run through every member and anchor into this cut-stone block, hidden inside the stone. The vault carries the roof in compression, and the steel handles what stone cannot. From form-finding to joinery, the roof is built from stone and carried by its own weight.