• Home
  • FT
  • SD4013-1
  • Analysis and Design of Transfer Tower: Staging Structure

Gaurav Singh

SD4013-1

Analysis and Design of Transfer Tower: Staging Structure

Design of an RCC battery silo of four 16 m diameter bins storing wheat, covering IS 4995 pressures, rigid-link modelling, and design of the wall, conical hopper and ring beam as per IS 456. This project details the structural planning and design of Transfer Tower TT6A, a 76.5 m, 13-storey braced steel staging structure in a coal handling plant with a 9 × 12 m plan. To ensure safety under lateral loads, the tower was analyzed for seismic forces as per IS 1893 Part 4 and for both static and dynamic gust-factor wind as per IS 875 Part 3, with the unscaled seismic base shear scaled up to meet the code minimum. The design focuses on flooring iterations, purlin, girt and monorail design, and on introducing an additional braced bay to provide a direct lateral load path and control deflection. Additionally, I compared static and dynamic wind effects, achieving a 9.5% saving in steel. This approach ensures every member, connection and base plate performs safely as per IS 800:2007, ensuring the overall structural integrity of the tower.

View Additional Work

Report Content

SILO DESIGN

PROJECT INTRODUCTION

DESIGN OF FLOORING SYSTEM, PURLIN & MONORAIL

EARTHQUAKE ANALYSIS

STATIC WIND ANALYSIS

DYNAMIC WIND ANALYSIS

BRACING & CRITICAL MEMBER DESIGN

STATIC vs DYNAMIC WIND

STEEL QUANTITY & BASE PLATES DESIGN

CONNECTIONS