This project assesses an existing RCC bank building in Ahmedabad and asks how well it would perform in an earthquake. A detailed site inspection recorded the building's condition and mapped visible damage such as cracking, corrosion, spalling and dampness. The structure was then modelled and analysed for seismic loading to Indian codes, revealing several beams and columns that would be overstressed. Suitable retrofitting techniques, including RCC jacketing, steel plate bonding and FRP strengthening, were designed for these members and checked again. Finally, a lab test on a strengthened beam showed how effectively these methods improve strength and stiffness.


Report Content

Case - Introduction

Working Drawings

Structural Analysis

Seismic Parameters

Beam Analysis

Retrofitting Strategies

Beam Retrofitting

Beam Retrofitting

Lab Test

Lab Test