  • REPAIRING AND STRENGTHENING OF G+10 STOREY RCC BUILDING

Tank Dhairy Sanjaybhai

SD4010

REPAIRING AND STRENGTHENING OF G+10 STOREY RCC BUILDING

This project involves the structural assessment and seismic strengthening of a G+10 RCC residential building located in Ahmedabad, Seismic Zone III. The existing structure was modelled and analysed in ETABS using both linear and nonlinear methods, including Pushover Analysis and Nonlinear Time History Analysis. The structure was found deficient in inter-storey drift, necessitating strengthening. Two strategies were evaluated — column and beam section enlargement, and addition of shear walls. Shear wall addition proved to be the most effective solution, significantly reducing top displacement and increasing base shear capacity, ensuring improved overall seismic resilience of the building.


Report Content

Project Introduction and ETABS Modelling

Modelling of Beam & Columns

Non-Linear Modelling

Pushover Analysis

Hinges Formation

Flexure Hinges Vs Shear Hinges, Strengthening Iterations

Strengthening Solution

Strengthening Result

Typical Strengthening Drawings

Time History Analysis