For a richer surfing experience on our website, please update your browser. Update my browser now!
This project focuses on the structural analysis and seismic design of a G+14 reinforced concrete residential building using ETABS and IS code provisions. The study began with gravity load assessment, preliminary member sizing, and slab design using the strip method. Static and dynamic seismic analyses were performed according to IS 1893:2016 to evaluate drift, displacement, torsional behavior, and structural performance.
Multiple structural iterations were developed by modifying beam and column dimensions to achieve serviceability and strength requirements. However, increasing frame member sizes alone resulted in impractical structural dimensions. To improve lateral stiffness and seismic behavior, peripheral shear walls were introduced strategically to reduce torsion, control drift, and optimize load distribution.
The final structural system demonstrated improved seismic performance, reduced displacement, better torsional control, and more efficient member sizing while maintaining functional architectural planning. The project concludes with detailed reinforcement drawings and ductile detailing of structural components in accordance with IS 13920:2016.