Urban Heat Island (UHI) studies in hot and dry cities like Ahmedabad often use satellite-derived land surface temperature (LST) to represent urban thermal conditions. However, its relationship with pedestrian-level air temperature is not always consistent at the street scale. This study examines the spatial and temporal relationship between near-surface air temperature (Ta) and façade surface temperature (Ts) across morphologically varied urban streets in Ahmedabad. Fourteen representative hotspots were identified using a GIS-based thermal screening approach and monitored through field measurements. Near-surface air temperature was measured at 1.5 m height, and façade surface temperature was recorded using thermal imaging in all four directions for all fourteen hotspots. Urban morphology parameters such as sky view factor (SVF) and canyon aspect ratio (H/W) were derived from hemispherical photography and geometric surveys, while surface radiative properties such as façade albedo were also documented. Pedestrian-level thermal comfort was assessed using the Universal Thermal Climate Index (UTCI). Measurements were conducted across three time slots in a day: morning, afternoon and night, over multiple days to capture diurnal variations.