A PHP Error was encountered

Severity: Notice

Message: Undefined offset: 0

Filename: models/Project_model.php

Line Number: 80

Backtrace:

File: /home/portfolio/public_html/application/models/Project_model.php
Line: 80
Function: _error_handler

File: /home/portfolio/public_html/application/models/Project_model.php
Line: 709
Function: get_sem_info

File: /home/portfolio/public_html/application/controllers/Project.php
Line: 112
Function: get_project_detail

File: /home/portfolio/public_html/index.php
Line: 321
Function: require_once

A PHP Error was encountered

Severity: Notice

Message: Undefined offset: 0

Filename: models/Project_model.php

Line Number: 80

Backtrace:

File: /home/portfolio/public_html/application/models/Project_model.php
Line: 80
Function: _error_handler

File: /home/portfolio/public_html/application/models/Project_model.php
Line: 800
Function: get_sem_info

File: /home/portfolio/public_html/application/controllers/Project.php
Line: 127
Function: increase_project_view

File: /home/portfolio/public_html/index.php
Line: 321
Function: require_once

A PHP Error was encountered

Severity: Notice

Message: Undefined offset: 0

Filename: models/Project_model.php

Line Number: 80

Backtrace:

File: /home/portfolio/public_html/application/models/Project_model.php
Line: 80
Function: _error_handler

File: /home/portfolio/public_html/application/helpers/utility_helper.php
Line: 131
Function: get_sem_info

File: /home/portfolio/public_html/application/views/includes/header.php
Line: 9
Function: semester_info

File: /home/portfolio/public_html/application/controllers/Project.php
Line: 148
Function: view

File: /home/portfolio/public_html/index.php
Line: 321
Function: require_once

DESIGN OF RCC HIGH-RISE BUILDING (MEDICAL CENTER) | CEPT - Portfolio
  • Home
  • FT
  • SD4006
  • DESIGN OF RCC HIGH-RISE BUILDING (MEDICAL CENTER)

Shah Hiren Jayeshbhai

SD4006

DESIGN OF RCC HIGH-RISE BUILDING (MEDICAL CENTER)

The Project was to Design & Analyse the High-Rise RCC building located  in EQ Zone V. Main problem statement was to Study behaviour of building with separation joint and without Separation Joint, Preparing various alternatives for details of treating separation joints, Check the effect of consideration of reduced MOI on requirements of separation joint. Design should be Earthquake resistant based. Member should be design as per Indian Standard.


Report Content

PROBLEM STATEMENT,ARCHITECTURAL PLAN,STRUCTURAL SYSTEM

LOAD CALCULATION AND ARRIVING TO INTIAL SIZING OF COLUMN SECTION, STATIC CHECK

WIND,EQ LOAD CALCULATION,COMPARISION IN RIGID FLOOR DIAPGRAM WITH OVERALL & WITHOUT MASTER SLAVE,INTER-STOREY DRIFT

BASE SHEAR DISTRIBUTED IN FRAME BEFORE AND AFTER SHEAR WALL INDUCED,CENTRE OF MASS & CENTRE OF STIFFNESS OF BOTH SYSTEM BEFORE AND AFTER ADDING OF SHEAR WALL

DISPLACEMENT PATTERN & STOREY SHEAR COMPARISON

COMPARATIVE ANALYSIS OF DIFFERENT FRAME BEAM & DIFFERENT COLUMN,MODAL SHAPES

PROVISION OF SEPARATION JOINT & NEW SYSTEM

SLAB DESIGN AND DETAILING

BEAM,COLUMN,FOOTING DETAILING DRAWING

SHEAR WALL,STAIRCASE DETAILING & CONCLUSION

Project Video