For a richer surfing experience on our website, please update your browser. Update my browser now!
This project comprises the complete structural analysis and design of an industrial warehouse, covering all primary and secondary structural members, along with the gantry girder. Plate sections were adopted for the main frames, while cold-formed sections were used for purlins and girts. A comparative study was carried out between gantry girders in laterally unsupported conditions and those laterally supported using a surge girder. For the heavy-duty gantry system, the optimum solution was identified as a laterally supported box-type gantry girder. Seismic loads were applied in accordance with IS 1893:2024, and wind loads were evaluated as per IS 875 (Part 3):2015. The structure had a span of 20 m; however, after the removal of two intermediate columns, the effective spans increased to 40 m in the X-direction and 21.75 m in the Z-direction.
View Additional Work