Chaudhary Kush Dineshbhai

CT2014

Hotel at Jaipur

This studio approaches plumbing design as an integrated building system rather than a collection of pipes and fixtures. To translate architectural requirements into water demand calculations, tank sizing, pumping systems, water treatment, rainwater harvesting, and distribution networks. Through the Hotel at Jaipur project, a complete plumbing design was developed, including supply and drainage layouts, vertical schematics, pressure zoning, and a Revit model. Sustainable water management and city-scale leak detection through Project AQUAS was also explored.


Report Content

Understanding water distribution, water consumption, plumbing systems, and good and bad plumbing practices through a hostel case study.

Investigating how water quality parameters influence the selection, performance, and durability of plumbing pipe materials.

Establishing the hotel’s design context, amenities, population, sustainability targets, and constraints to define the plumbing requirements.

Quantifying the hotel's water demand by activity and use, establishing the total daily consumption and water balance.

Designing rainwater harvesting, percolation wells, heat pump systems, pumps, STP, freshwater reduction strategies, and tank capacities.

Mapping the flow of water through treatment, storage, consumption, recycling, and reuse systems to understand the hotel's overall water cycle.

Developing vertical supply schematics, floor-wise distribution, duct routing, and pressure zones to ensure reliable water delivery throughout the building.

Translating calculations into floor layouts, toilet block details, pipe routing, and a coordinated 3D plumbing model using Revit.

Exploring city-scale leak detection through a sensor-based network, working prototype, monitoring dashboard, and preliminary implementation cost estimation.

Studying real-world plumbing materials, manufacturing processes, drainage systems, and industry practices through visits to Kitec, ACO, and Astral.