Hira Maqboolhusain Asgarali

SD4007-1

DESIGN OF GRID SHELL STRUCTURE USING TIMBER

This report presents a timber grid shell structure for the University Convocation registration desk at CEPT University's Workshop Area, Ahmedabad. After three form iterations, a continuous 1000 mm grid roof, 24 m long and 4.5 m high, was chosen, covered with PTFE membrane. Loads travel from grid ribs to side members, then to supports and three columns. STAAD Pro analysis, validated by hand calculations, shows all oak members within IS 883:2016 stress. The largest grid member (250 x 500 mm) is hard to source in natural timber, so engineered timber with steel plate connections is recommended.


Report Content

SITE INFORMATION AND FORM FINDING

CASE STUDY AND FINAL FORM

LOAD TRANSFER AND MATERIAL PROPERTIES

MANUAL CALCULATIONS

STRUCTURAL MEMBERS BEHAVIOUR

INITIAL MEMBER SIZES ANALYSIS AND BEHAVIOUR

STIFFENED GRID ANALYSIS AND BEHAVIOUR

SUPPORTING MEMBERS ANALYSIS AND BEHAVIOUR

FINAL SIZING

STRUCTURAL BEHAVIOUR, CONNECTION DETAILS AND CONCLUSION