Rajput Aryansinh Sandipkumar

SD4007-2

Balanced Cantilever Parking Canopy

The project explores the design of a bamboo parking canopy in Zone 1, covering a site measuring 45 m × 16.21 m. The objective is to create a lightweight, sustainable shelter using bamboo as the primary structural material while maintaining an open parking area and an uninterrupted pedestrian route. The structural concept is based on a balanced cantilever system, where bundled bamboo columns branch outward into curved arms supporting roof trusses on both sides. The form evolved through sketches, physical models and structural studies, transitioning from two large canopy structures to five smaller, repeatable modules along the parking edge. The design draws inspiration from the Huanglong Waterfront Bamboo Pavilion in China and Oneness Rishikesh in India. Bambusa balcooa is adopted for the primary columns and trusses, while Tulda bamboo is proposed for purlins and roof shingles. The roof assembly combines bamboo shingles, waterproof underlay and bamboo backing. Loads are transferred through the purlins to the trusses, branching columns and foundations. Manual calculations and STAAD.Pro analysis were used to examine gravity loads, wind pressure and suction, member stresses, axial forces, bending moments and deflections. Structural refinement introduced a three-dimensional truss arrangement and intermediate support, reducing the reported maximum displacement from 33.790 mm to 25.091 mm, within the adopted 30 mm limit. The project demonstrates how form finding, bamboo bundling, structural analysis and connection development can inform an efficient modular parking canopy. Further verification of connection behaviour and construction detailing is required before implementation.


Report Content

The proposed balanced cantilever parking canopy uses bamboo as the principal structural material in Zone 1. The assigned strip is 45 m long and 16.21 m wide. The slide introduces the parking function, site plan, canopy elevation and source material specifications for Bambusa balcooa and Tulda bamboo.

Early sketches explored two large 11.50 m cantilevers on either side of the main columns. Physical prototypes tested single curved arms, balanced paired arms and crossing arms before the design developed into a repeating canopy system. The slide documents truss geometry and the initial parking-shelter proposal.

The Huanglong Waterfront Bamboo Pavilion in China illustrates double-sided cantilever canopies supported by compact central trunks and reinforced by concealed steel. Oneness Rishikesh in India demonstrates bundled, interconnected bamboo arches. These precedents informed the concept of branching supports, bundled members and spatial load transfer.

The design was refined from two large roofs into five smaller modules repeated along the 45 m parking edge. Curved bamboo members branch from each central column to form lower truss chords, while upper chords, diagonal webs and transverse ties create the supporting spatial framework. Site diagrams show the parking area and continuous pedestrian route.

Roof loads are transmitted from the roof covering through the purlins and trusses to the branching columns and foundations. The proposed assembly comprises 12 mm Tulda bamboo shingles, 3 mm waterproof asphalt underlay and 22 mm bamboo backing. The slide reports a combined roofing dead load of approximately 0.273 kN/m².

The design study considers roof live loads, wind pressure, wind suction and asymmetric loading across the two cantilever sides. STAAD.Pro diagrams illustrate the roof framework, truss model, central supports and loading arrangements. Five primary cases are described: self-weight, dead load, live load, wind pressure and wind suction.

Cross-section studies compare single culms with side-by-side, vertical and multi-culm bundles. A four-culm purlin arrangement was checked for bending and deflection across a 5.50 m span. Excessive deformation of the initial 5.368 m supporting cantilever motivated the introduction of deeper truss geometry.

The presentation compares axial forces and bending moments in a 2D truss and a 3D space-truss study. Reported peak compression decreases from 49.2 kN to 24.6 kN, while peak tension changes from 39.9 kN to 39.5 kN. The recorded truss deflections are also compared against an adopted L/240 limit.

STAAD.Pro results illustrate tension, compression and combined axial-plus-bending stresses in the upper chords, lower chords and diagonal webs. Single bamboo culms are studied in the upper chords and webs, while paired vertical culms are examined in the lower chords. The tables document how the different member groups respond to loading.

The revised canopy introduces a central truss that reduces purlin span from 5.50 m to 2.75 m and links adjacent trusses spatially. The reported maximum deflection decreases from 33.790 mm to 25.091 mm, below the adopted 30 mm limit. The final column concept comprises 32 Bambusa balcooa culms, with four rising vertically and 28 branching out, alongside proposed joinery details.