Ghosh Suhena Hari Santana

SD4010

Partially Collapsed Masonry Structure

This project investigates the structural behaviour and seismic performance of a partially collapsed Grade–1 heritage masonry building in Kalupur, Ahmedabad. Detailed visual inspection, damage assessment and finite element modelling were carried out using DIANA FEA to analyse the existing structural system. Linear static, eigenvalue, pushover, and nonlinear time history analyses using Bhuj earthquake records were performed to evaluate global response, drift behaviour, and load-carrying capacity. A parametric study examined the influence of masonry material properties on seismic performance. Based on the findings, heritage-sensitive repair and retrofitting techniques were proposed to restore structural integrity while preserving architectural authenticity. 


Report Content

Introduction to Site

Architectural Plans

Visual Inspection of the Structure

Diana FEA Modelling

Structural Behaviour

Pushover Analysis - X

Pushover Analysis - Y

Parametric Study

Time History Analysis

Repair & Retrofit Solutions