Thermal comfort research has conventionally emphasized thermal neutrality particularly in
steady state conditions, with limited attention to thermal pleasure and hedonic valence in
transient outdoor environments. Thermal alliesthesia, a state-dependent psychophysiological
phenomenon describes how identical thermal stimuli may be perceived as pleasant or
unpleasant depending on the human body’s thermoregulatory state. Despite its relevance, it
remains largely absent from thermal environment design. This paper investigates thermal
alliesthesia as a quantitative design assistance metrics for thermal pleasure under warm
outdoor heat stress conditions. The objective is to determine a range of surface temperatures
that can be applied to local body segments in outdoor seated conditions to induce sufficient
thermal pleasure. These temperature ranges are evaluated for their ability to shift whole-body
thermal comfort vote (TCV) from discomfort (due to warm baseline conditions) toward near
comfortable across environmental stress levels defined by the Universal Thermal Climate
Index (UTCI). The paper also quantifies the duration of thermal pleasure by examining the
dynamic sensation time prior to sensory adaptation. The simulation framework involves
coupling JOS-3 multi-segment thermoregulation model with thermal sensation and comfort
models for non-uniform and transient environments. Numerical simulations were performed
for moderate to extreme heat stress conditions (UTCI 26–58 °C) for the city of Ahmedabad
across four conductive cooling configurations: seat cooling, backrest cooling, combined seat - backrest cooling, and a multi-segment case including hands and legs. Results indicate that
localized conductive cooling can elicit positive alliesthesial responses by improving whole
body thermal comfort vote even under severe heat stress. Comfort peaks during the post-onset
transient phase before gradually declining with sensory adaptation. Required surface
temperatures decrease with increasing UTCI. Multi-segment stimulation enhances both peak
and adapted TCV, while further improvements in local comfort vote show diminishing
influence on whole-body comfort perception beyond a threshold.