DESIGN OF G+10 BUILDING FOR DIFFERENT ASPECT RATIO

This project examined the plan aspect ratio (length-to-width ratio in the horizontal plane) of three buildings with different footprints. The aim was to understand how plan proportions affect structural behavior, including load paths, diaphragm action, and lateral stability under wind and seismic forces. The comparison highlighted how buildings with extreme plan ratios—either very elongated or nearly square—present unique structural challenges, influencing design choices such as shear wall placement and load distribution efficiency.  


Report Content

PROJECT INFORMATION

STATIC CHECK

SEISMIC FORCE CALCULATION

INITIAL SYSTEM & SMRF SYSTEM

FINAL MODEL (DUAL SYSTEM)

CHECK FOR DUAL SYSTEM

FRAME PARTICIPATION

RESULT OF LATERAL FORCES( STATIC & DYNAMIC) & COLUMN-WALL INTERACTION

DYNAMIC ANALYSIS(UNSCALED)

BEAM DETAILING